Regulator Service Intervals and Bench Specs, by Model

The service interval and the bench settings our technicians work to for every regulator model we certify, straight from the manufacturers’ service documentation. Use it to check a used regulator, or to see when yours is due.

Intermediate pressure is measured with the first stage pressurized and no flow; it must reach the range and hold there without creeping. Cracking effort is the inhalation pressure at which the second stage begins to flow, measured in inches of water. Where a manufacturer publishes a dive count as well as a calendar interval, whichever comes first applies.

Every certified used regulator on DescendAgain is tuned to these numbers and the measurements are recorded against its serial number. Click a model for its page: what is in stock, what has sold, and the full spec.

Aeris · AP Diving · Apeks · Apeks (military/defence) · Aqua Lung · Aqua Lung (La Spirotechnique) · Aqua Lung (military) · Aqua Lung / US Divers · Aquatec · Atomic · Beuchat · Coltri / Mch · Cressi · Dacor · Deep 6 · Deep6 · DGX · Dive Rite · Divesystem · Draeger · Drager · EDGE · Genesis · H2Odyssey · Halcyon · Healthways · Highland · HOG · HOG/Edge · Hollis · IDI · Interspiro · IST · IST/Proline · Kirby Morgan · La Spirotechnique · Mares · Nemrod · Oceanic · OMS · Poseidon · Problue · Scubair · Scubapro · Scubatech · Seac · SeaQuest · Sherwood · Spiro (La Spirotechnique) · Spirotechnique · Sportsways · Subgear · Swimaster · Technisub · Tecline / Scubatech · Tusa · US Divers · US Divers/Aqua Lung · Voit · Voit/AMF Swimaster · Voit/Swimaster · Voit/Voit Swimaster · White Stag · XS Scuba · Zeagle

Aeris

ModelServiceBench spec
A1every 12 months
A2every 12 months
AT400every 12 monthsFirst: 138 - 142 PSI; First: 138 - 142 PSI
AT400 DVTevery 12 monthsFirst: 138 - 142 PSI
AT600every 12 months
Atmosevery 12 months
Ionevery 12 months
Octopusevery 12 monthsSecond: 1.0 - 1.5 in H2O
TX50every 12 months
XR-1every 12 months

AP Diving

ModelServiceBench spec
Diluent Sideevery 12 monthsFirst: 135 - 139 PSI
O2 Sideevery 12 monthsFirst: Max. 110 PSI

Apeks

ModelServiceBench spec
AT20every 24 monthsFirst: 130 - 145 PSI; Second: +0.8 to +1.4 in H2O (at IP 135 ±5 psi)
ATX100every 24 monthsSecond: +0.8 to +1.4 in H2O (at IP 135 ±5 psi); First: 130 - 145 PSI
ATX200every 12/24 monthsSecond: +0.8 to +1.4 in H2O (at IP 135 ±5 psi); First: 130-145 psi
ATX40every 24 monthsSecond: +0.8 to +1.4 in H2O (at IP 135 ±5 psi); First: 130 - 145 PSI; Second: +0.8 to +1.4 in H2O (at IP 135 ±5 psi)
ATX50every 24 monthsSecond: +0.8 to +1.4 in H2O (at IP 135 ±5 psi); First: 130 - 145 PSI
DS4every 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
DSTevery 24 monthsFirst: 135 psi ±5 (130-140 psi)
DST4every 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
Egressevery 24 monthsSecond: 1.0 - 1.5 in H2O; First: 130 - 145 PSI; Second: 1.0 - 1.5 in H2O
EVXevery 24 months
Flightevery 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
FSRevery 24 months
FSTevery 24 months
Mantaevery 24 months
MTX-Revery 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
MTX-RCevery 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
TEK3every 24 monthsFirst: 130 - 145 PSI; First: 130 - 145 PSI; Second: 1.0 - 1.5 in H2O
TX100every 24 months
TX200every 24 months
TX40every 24 months
TX50every 12/24 monthsSecond: 1.0 - 1.5 in H2O; First: 135 psi ±5 (130-140 psi)
US4every 24 months
USTevery 24 months
XL4every 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual; First: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
XL4 Oceaevery 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
XTX100every 24 monthsSecond: 1.0 - 1.5 in H2O; First: 130 - 145 PSI
XTX20every 24 monthsFirst: 130 - 145 PSI; Second: 1.0 - 1.5 in H2O
XTX200every 24 monthsSecond: 1.0 - 1.5 in H2O; First: 130 - 145 PSI
XTX40every 24 monthsSecond: 1.0 - 1.5 in H2O; First: 130 - 145 PSI
XTX50every 24 monthsSecond: 1.0 - 1.5 in H2O; First: 130 - 145 PSI

Apeks (military/defence)

ModelServiceBench spec
DS4every 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
MTX-Revery 24 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual

Aqua Lung

ModelServiceBench spec
ABSevery 24 monthsSecond: 0.8 - 1.8 in H2O
Air Source 2every 24 monthsSecond: 1.3 - 2.0 in H2O
Air Source 3every 24 monthsSecond: +1.8 to +2.6 in H2O (4.5-6.5 mbar)
Calypsoevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Conshelf SEevery 24 months
Conshelf SE2every 24 months
Conshelf SE3every 24 months
Conshelf Supremeevery 24 months
Conshelf XIV Supremeevery 24 months
Coreevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Core Supremeevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Glaciaevery 12 monthsFirst: 130-135 psi; Second: +1.0 to +1.6 in H2O
Helixevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Helix Compact Proevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Helix Proevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Kronosevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Kronos Supremeevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Leg3ndevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Leg3nd Eliteevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Leg3nd MBSevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Legendevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar); First: 135 PSI +/- 5 PSI; Second: 1.0 - 1.5 in H2O
Legend ACDevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Legend Eliteevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Legend Glaciaevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Legend LUXevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
Legend LXevery 24 monthsFirst: 125 - 145 PSI; Second: +0.8 to +1.4 (Legend LX 2nd-stage manual, Table 5 "Opening Effort"); Second: 1.0 - 1.5 in H2O
Legend LX Supremeevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar); Second: +0.8 to +1.4 (max @ 15 SCFM; same manual)
Legend Supremeevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
LPOevery 24 monthsSecond: 1.4 - 2.0 in H2O
LXevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Micraevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Mikronevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar); First: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Mistralevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Octopusevery 24 monthsSecond: 1.4 - 2.0 in H2O
Titanevery 12/24 monthsFirst: 135 (±5) psi; Second: +0.8 to +1.4 in H2O (at inlet 2,500-3,000 psi, IP 135 ±5 psi); Second: +0.8 to +1.4 in H2O
Titan LXevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Titan LX Supremeevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)

Aqua Lung (La Spirotechnique)

ModelServiceBench spec
Cristalevery 24 months

Aqua Lung (military)

ModelServiceBench spec
Legendevery 24 monthsFirst: 135-145 psi (9.3-10.0 bar)
MTXevery 24 months

Aqua Lung / US Divers

ModelServiceBench spec
Conshelf SE2every 24 months
Conshelf XIVevery 24 months
Cousteauevery 24 months
Mistralevery 24 months

Aquatec

ModelServiceBench spec
RG-1100Fevery 12 monthsFirst: 130-142 psi (9-9.8 bar)
RG-1100F_Bevery 12 monthsFirst: 130-142 psi (9-9.8 bar)
RG-2100Fevery 12 monthsFirst: 135-145 psi (9.5-10.2 bar)
RG-2105Fevery 12 monthsFirst: 135-145 psi (9.5-10.2 bar)
RG-2200Fevery 12 monthsFirst: 135-145 psi
RG-3100Fevery 12 monthsFirst: 135-145 psi (9.5-10.2 bar)
RG-4100Fevery 12 monthsFirst: 135-145 psi (9.5-10.2 bar)

Atomic

ModelServiceBench spec
B1every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O; Second: 1.0 - 1.4 in H2O
B2every 24/36 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O; Second: 1.0 - 1.4 in H2O
B2xevery 24 monthsSecond: 1.0 - 1.4 in H2O
M1every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
SS1every 24 monthsSecond: 1.0 - 1.4 in H2O; Second: 1.0 - 1.4 in H2O
ST1every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
T1every 24 monthsFirst: 125 - 145 PSI; Second: 1.25 - 1.5 in H2O; First: 125 - 145 PSI; Second: 1.25 - 1.5 in H2O
T1Xevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
T2every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
T2xevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O; First: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
T3every 36 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
TFXevery 24 monthsFirst: 135-140 psi (9.3-9.7 bar) (adjustable); Second: 1.1 - 1.2 in H2O (with 145 psi supply air)
Z1every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
Z2every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O; Second: 1.0 - 1.4 in H2O
Z2Xevery 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O
Z3every 24 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.4 in H2O

Beuchat

ModelServiceBench spec
Souplairevery 12 months
V-Firstevery 12 months
V-Twinevery 12 months
VR 200every 12 months
VR200 Soft Touch HFevery 12 monthsFirst: 145 psi (9.5 bar) above ambient
VRT 30every 12 monthsFirst: 145 psi (9.6 bar) above ambient
VRT 400every 12 months
VRT 80every 12 monthsFirst: 145 psi (9.6 bar)
VRT 90every 12 months
VS2every 12 monthsFirst: 145 psi (9.6 bar) — sourced for VS3 only; VS2 not covered by any source found
VX10every 12 months
VX10 Icebergevery 12 monthsFirst: 145 psi (9.5 bar) above ambient
VX100every 12 months
VX200every 12 monthsFirst: 145 psi (9.5 bar)
VX4 Evolutionevery 12 months
VX80every 12 monthsFirst: 145 psi (9.6 bar) above ambient

Coltri / Mch

ModelServiceBench spec
Ocean 90every 12 months
Ocean C11000every 12 months
Ocean C9000every 12 months
Polarisevery 12 months

Cressi

ModelServiceBench spec
AC10every 12 monthsFirst: 146 psi (+0/-7 psi)
AC10Vevery 12 monthsFirst: 130-140 psi (9.0-9.7 bar)
AC2every 12 monthsFirst: 138-146 psi (9.5-10 bar)
AC25every 12 monthsFirst: 138-146 psi (9.5-10 bar)
AC25mevery 12 monthsFirst: 138-146 psi (9.5-10 bar)
Compactevery 12 monthsSecond: 1.2-2.0 in H2O
Ellipseevery 12 months
Ellipse Balancedevery 12 months
Ellipse Steelevery 12 months
Ellipse Titaniumevery 12 months
Frogevery 12 months
Galaxyevery 12 monthsSecond: 1.1 - 1.4 inwg (in H2O); source also states 2.5 - 3.5 mbar (~2.5 - 3.5 cm H2O). Measured on bench with 1st stage IP at 9.5-10 bar / 138-146 psi.
Galaxy Adjustable Revery 12 monthsSecond: 1.1 - 1.4 inwg (in H2O), knob fully open; source also states 2.5 - 3.5 mbar (~2.5 - 3.5 cm H2O).
Masterevery 12 monthsSecond: 1.1 - 1.4 inwg (in H2O), inhalation-effort knob fully open; source also states 2.5 - 3.5 mbar (~2.5 - 3.5 cm H2O).
Master Galaxyevery 12 months
MC5every 12 monthsFirst: 146 psi
MC9every 12 monthsFirst: 138-146 psi (9.5-10 bar)
MC9-SCevery 12 monthsFirst: 138-146 psi (9.5-10 bar)
Nanoevery 12 months
Octo MG Balancedevery 12 monthsSecond: 1.1 - 1.4 inwg (in H2O); source also states 2.5 - 3.5 mbar (~2.5 - 3.5 cm H2O).
Polarisevery 12 months
T10every 12 monthsFirst: 146 psi (+0/-7 psi)
T10-SCevery 12 monthsFirst: 138-146 psi (9.5-10 bar)
XS Compactevery 12 monthsSecond: 1.2-2.0 in H2O; First: 145 PSI +/- 3 PSI; Second: 1.2-2.0 in H2O
XS2every 12 monthsSecond: 1.6 - 2 inwg (in H2O); source also states 4 - 5 mbar (~4 - 5 cm H2O).

Dacor

ModelServiceBench spec
960every 12 months
Clipper C-2every 12 months
Enduroevery 12 months
Extremeevery 12 monthsFirst: 140 psi ±4 (136-144 psi)
Furyevery 12 monthsSecond: +1.0 to +1.5 in H2O (Classic / Classic Pro / Eagle primary 2nd stage; Eagle octopus +1.2 to +1.6 in H2O). Source does NOT cover Fury or Fury Adj.
Olympic 100every 12 months
Pacerevery 12 months
Quantumevery 12 months
R-1every 12 months
Viperevery 12 months

Deep 6

ModelServiceBench spec
Excursion Series 1st stageevery 24 monthsFirst: 138 psi (tune at 500 psi tank); 125-145 psi at all tank pressures 500-3000 psi, with no IP creep
Signature Series 1st stageevery 24 monthsFirst: 138 psi (tune at 500 psi tank); 125-145 psi at all tank pressures 500-3000 psi, with no IP creep

Deep6

ModelServiceBench spec
Signatureevery 12 monthsSecond: 0.7-1.5 acceptable range (VERIFIED, Deep6 Signature svc manual p.50)
Signature Octoevery 12 monthsSecond: 0.7-1.5 (VERIFIED, same manual)

DGX

ModelServiceBench spec
DGX Gears D6every 24 monthsFirst: 135 psi ±5 (130-140 psi)
DGX Gears Gas Switch 1st stageevery 12 months

Dive Rite

ModelServiceBench spec
FT1every 12 months
Hurricaneevery 12 monthsSecond: 0.6 - 0.8 in H2O; First: 135 - 145 PSI
Jetstreamevery 12 months
RG1100every 12 months
RG1200every 12 months
RG1205every 12 months
RG1208 Blackevery 12 months
RG1210every 12 months
RG1215 Octoevery 12 months
RG2010every 12 months
RG2015every 12 months
RG2500every 12 months
RG3000every 12 months
RG3500 "Hurricane"every 12 months
XT1every 12 monthsSecond: 0.8-1.0 (same OEM body as XT2)
XT2every 12 monthsSecond: 0.6 - 0.8 in H2O; First: 135 - 145 PSI
XT4every 12 months

Divesystem

ModelServiceBench spec
X-Adv Pixevery 12 months
X-Tech CLVevery 12 months

Draeger

ModelServiceBench spec
LAR 8000every 12 months
LAR Vevery 12 months
LAR VI.1every 12 months
PA-61every 12 months
Secor 7000every 12 months
Sharkevery 12 months

Drager

ModelServiceBench spec
Secor 7000every 12 months
Sharkevery 12 months

EDGE

ModelServiceBench spec
EDGE diaphragm 1st stageevery 24 months

Genesis

ModelServiceBench spec
Argoevery 12 months
Atlasevery 12 monthsFirst: 140 psi ±5 (135-145 psi), with inlet pressure 2,500-3,000 psi
D.A.D. First Stageevery 12 monthsFirst: 140 psi ±5 (135-145 psi), with inlet pressure 2,500-3,000 psi
DADevery 12 monthsFirst: 130 - 150 PSI
GS seriesevery 12 monthsSecond: 1.0 to 1.4 in H2O with adjustment knob set 1-1/2 turns in clockwise. Flowbench limits: not to exceed 1.0 in H2O knob out (CCW), 2.5 in H2O knob fully in (CW)
GS2000every 12 monthsFirst: 140 psi ±5 (135-145 psi), with inlet pressure 2,500-3,000 psi; Second: 1.0 - 1.5 in H2O
Octoevery 12 months
Pranaevery 12 months
Reactevery 12 months
Sidekickevery 12 monthsSecond: Opening effort not to exceed 1.5 - 2.0 in H2O
SKOevery 12 monthsSecond: Opening effort not to exceed 1.5 - 2.0 in H2O
Yukonevery 12 monthsFirst: 140 psi ±5 (135-145 psi), with inlet pressure 2,500-3,000 psi

H2Odyssey

ModelServiceBench spec
RG-V2every 12 months
RG-V3every 12 months

Halcyon

ModelServiceBench spec
Auraevery 12 months
H-50Devery 12 monthsFirst: 9-9.8 bar (130-142 psi)
H-75Pevery 12 monthsFirst: 9-9.8 bar (130-142 psi)
Haloevery 12 months

Healthways

ModelServiceBench spec
Model SCUBAevery 12 months
Scuba Starevery 12 monthsFirst: 135 +/-5 psi (9.3 +/-0.3 bar)
Scubairevery 12 months
Scubair Jevery 12 months
Scubair Sonicevery 12 months
SRB 3200every 12 monthsFirst: 135-150 psi (9-10 bar) interstage; lock-up should settle around 145 psi. Below 135 psi add shims (max 3); above 150 psi remove shims. Never set first-stage output above 150 psi.

Highland

ModelServiceBench spec
Compactevery 12 months

HOG

ModelServiceBench spec
D1every 12 monthsFirst: 135 psi ±5 (130-140 psi)
D1Xevery 24 months
D2every 24 months
D3every 12 monthsFirst: 135 psi ±5 (130-140 psi)
Rec-Tekevery 24 months

HOG/Edge

ModelServiceBench spec
Classicevery 24 months
D3 2nd stageevery 24 months
Octo variantsevery 24 months
Zenithevery 24 months

Hollis

ModelServiceBench spec
100LXevery 12 monthsSecond: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative; adjust/test at first-stage IP 144 psi +/- 2 (9.9 bar +/- 0.14)
150LXevery 12 monthsSecond: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative; adjust/test at first-stage IP 144 psi +/- 2 (9.9 bar +/- 0.14)
200LXevery 12 monthsSecond: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative, adjustment knob fully out; adjust/test at first-stage IP 144 psi +/- 2 (9.9 bar +/- 0.14)
210every 12 months
212every 12 monthsSecond: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative; adjust/test at inlet IP 144 psi +/- 2 (9.9 bar +/- 0.14), supply 3000 psi; Second: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative; adjust/test at inlet IP 144 psi +/- 2 (9.9 bar +/- 0.14), supply 3000 psi
221every 12 monthsSecond: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative; adjust/test at inlet IP 144 psi +/- 2 (9.9 bar +/- 0.14), supply 3000 psi
321every 12 monthsSecond: Inhalation (cracking) effort not to exceed 1.4 in H2O (IWC), venturi switch set negative; adjust/test at inlet IP 144 psi +/- 2 (9.9 bar +/- 0.14), supply 3000 psi
500SEevery 12 monthsSecond: Opening (cracking) effort at IP = 140 psi: recommended setup 1.1 to 1.4 inches of water; acceptable setup 1.0 to 1.6 inches of water
DC1every 12 monthsFirst: 138 to 142 psi (9.5-9.8 bar) preferred; acceptable 137 to 143 psi (9.4-9.86 bar) [rev r02, 8/27/11 — supersedes rev r01 which specified 143-145 psi preferred / 142-146 acceptable]
DC2every 12 monthsFirst: 143 to 145 psi (9.9-10 bar) preferred; acceptable 142 to 146 psi (9.8-10.1 bar)
DC3every 12 monthsFirst: Preferred 138 psi (9.5 bar); acceptable 134-142 psi. Final adjustment: set 137 to 139 psi (9.4-9.6 bar), must not creep/fluctuate more than 5 psi
DC7every 12 monthsFirst: Preferred 138 psi (9.5 bar); acceptable 134-142 psi. Final adjustment: set 137 to 139 psi (9.4-9.6 bar), must not creep/fluctuate more than 5 psi
DCXevery 12 monthsFirst: Preferred 138 psi (9.5 bar); acceptable 134-142 psi. Final adjustment: set 137 to 139 psi (9.4-9.6 bar), must not creep/fluctuate more than 5 psi
H-O2every 12 monthsFirst: 140-150 psi (9.7-10.3 bar) with 3000 psi supply; 120-130 psi (8.3-9 bar) with 500 psi supply. Set by shims. IP below 135 psi = weak valve spring, replace

IDI

ModelServiceBench spec
Ospreyevery 12 months

Interspiro

ModelServiceBench spec
Divatorevery 12 monthsSecond: 15-40mm water column (~0.6-1.6 in H2O) (Interspiro/AGA svc manual)
Divator MK IIevery 12 monthsFirst: 7.5 bar (109 psi) dynamic secondary (intermediate) pressure. Manufacturer nominal value - no +/- service tolerance published. NOTE: sec. 6.2.1 of the same manual says the first stage reduces cylinder pressure to "approximately 8 bar (116 psi)".
Divator MK IIIevery 12 monthsFirst: 8.5 bar (123 psi) dynamic intermediate pressure. Manufacturer nominal value from the MKIII manual's "Working principle" section - no +/- service tolerance published. Regulator holds output down to a supply pressure of approx. 15 bar (218 psi).
Divator SCUBAevery 12 months

IST

ModelServiceBench spec
"Premium" DIN pistonevery 12 monthsFirst: 137-145 psi (9.5-10.0 bar)
Octopusevery 12 months
R-7every 12 monthsFirst: 137-145 psi (9.5-10 bar)
R-860every 12 monthsFirst: 135-145 psi (9.3-10 bar) per IST owner's manual; IST product page lists 137-145 psi (9.5-10.0 bar)
R410every 12 monthsSecond: 1.2-1.4 in H2O (IST owner's manual)
R750every 12 monthsSecond: 1.2 in H2O (IST product/spec page)
R860every 12 monthsSecond: 0.8-1.2 in H2O

IST/Proline

ModelServiceBench spec
R-750every 12 monthsFirst: 137-145 psi (9.5-10 bar)

Kirby Morgan

ModelServiceBench spec
Metal SuperFlow scuba 1st stageevery 12 monthsFirst: 135-145 psig (9.3-10 bar)
Plastic SuperFlow scuba 1st stageevery 12 monthsFirst: 135-145 psig (9.3-10 bar)

La Spirotechnique

ModelServiceBench spec
Aquilonevery 12 months

Mares

ModelServiceBench spec
12Severy 24 monthsFirst: 142 - 148 PSI
15every 24 monthsFirst: 142 - 148 PSI
22 Navyevery 12 monthsFirst: 127-136 psi
22Xevery 24 monthsFirst: 142 - 148 PSI
25XRevery 24 monthsFirst: 142 - 148 PSI
28XRevery 24 monthsFirst: 142 - 148 PSI
2Severy 24 monthsFirst: 142 - 148 PSI
42Tevery 24 monthsFirst: 142 - 148 PSI
52every 24 monthsFirst: 142 - 148 PSI
62Xevery 24 monthsFirst: 142 - 148 PSI
72Xevery 24 monthsFirst: 142 - 148 PSI
75XRevery 24 monthsFirst: 142 - 148 PSI
82Xevery 24 monthsFirst: 142 - 148 PSI
Abyssevery 24 monthsSecond: 1.0 - 1.5 in H2O; Second: 1.0 - 1.5 in H2O
Akrosevery 24 monthsSecond: 1.0 - 1.5 in H2O
Axisevery 24 monthsSecond: 1.0 - 1.5 in H2O
Dragonevery 24 monthsSecond: 1.0 - 1.5 in H2O
Dualevery 24 monthsSecond: 1.0 - 1.5 in H2O
Dual ADJevery 24 monthsSecond: 1.0 - 1.5 in H2O
Epic 82Xevery 24 monthsSecond: 1.0 - 1.5 in H2O
Epic ADJevery 24 monthsSecond: 1.0 - 1.5 in H2O
Eposevery 24 monthsSecond: 1.0 - 1.5 in H2O
Fusionevery 24 monthsSecond: 1.0 - 1.5 in H2O
Instinctevery 24 monthsSecond: 1.0 - 1.5 in H2O
MR10every 24 monthsFirst: 142 - 148 PSI
MR12every 24 monthsFirst: 142 - 148 PSI
MR12 IIIevery 24 monthsFirst: 142 - 148 PSI
MR16every 24 monthsFirst: 142 - 148 PSI; First: 142 - 148 PSI
MR22every 24 monthsFirst: 142 - 148 PSI; First: 142 - 148 PSI
MR32every 24 monthsFirst: 142 - 148 PSI
MR42every 24 monthsFirst: 142 - 148 PSI
MR42 Carbonevery 24 monthsFirst: 142 - 148 PSI; Second: 1.0 - 1.5 in H2O
Orbiterevery 24 monthsSecond: 1.0 - 1.5 in H2O
Prestigeevery 24 monthsSecond: 1.0 - 1.5 in H2O
Protonevery 24 monthsSecond: 1.0 - 1.5 in H2O; First: 142 - 148 PSI; Second: 1.0 - 1.5 in H2O
Proton Iceevery 24 monthsSecond: 1.0 - 1.5 in H2O
Proton Metalevery 24 monthsSecond: 1.0 - 1.5 in H2O
R2every 24 monthsFirst: 142 - 148 PSI; First: 142 - 148 PSI
Rebelevery 24 monthsFirst: 142 - 148 PSI; Second: 1.0 - 1.5 in H2O
Roverevery 24 monthsSecond: 1.0 - 1.5 in H2O
Rover Octopusevery 24 monthsSecond: 1.0 - 1.5 in H2O
Rubyevery 24 monthsSecond: 1.0 - 1.5 in H2O; First: 142 - 148 PSI
Ti Planetevery 24 monthsFirst: 142 - 148 PSI
Ultra 72Xevery 24 monthsSecond: 1.0 - 1.5 in H2O
Ultra 82Xevery 24 monthsSecond: 1.0 - 1.5 in H2O
V16every 24 monthsFirst: 142 - 148 PSI
V22every 24 monthsFirst: 142 - 148 PSI
V32every 24 monthsFirst: 142 - 148 PSI
V42 LE Metalevery 24 monthsFirst: 142 - 148 PSI

Nemrod

ModelServiceBench spec
Escafandra Autonomaevery 12 months
Meteor Jevery 12 months
Saturnevery 12 months
Snark IIevery 12 months
Snark IIIevery 12 months
Snark III Silverevery 12 months
Snark III Superevery 12 months

Oceanic

ModelServiceBench spec
AIR XS 2every 12 monthsSecond: 1.6 to 2.2 in H2O (3.8 to 5.6 cm H2O), Opening Effort at IP = 144 psi / 10 BAR
Alpha 7every 12 months
Alpha 8every 12 monthsSecond: 1.0 - 1.5 in H2O; Second: 1.1 - 1.5 in H2O primary (octopus 1.5 - 2.2; acceptable 1.0 - 2.5) at IP 138 psi
CDXevery 12 monthsFirst: 134 - 142 psi (set with supply pressure 500-3000 psi)
CDX-5every 12 monthsFirst: 137 - 139 psi (preferred 138 psi)
CDX5every 12 monthsFirst: 137 - 139 psi (preferred 138 psi)
Delta 2every 12 months
Delta 3every 12 monthsSecond: 1.0 - 1.5 in H2O
Delta 4every 12 monthsSecond: 1.2 in H2O or less (minimum effort with no leak), at IP 138 psi
Delta 4.1every 12 monthsSecond: 1.0 - 1.5 in H2O
Delta 5every 12 months
DX2every 12 months
DX3every 12 months
DX4every 12 monthsFirst: 140 +/-5 psi (9.5 +/-0.3 bar)
EDXevery 12 monthsFirst: 134-142 psi (supply 500-3000 psi)
EOSevery 12 monthsSecond: <=1.2 IWC at IP 140 (VERIFIED, EOS svc procedure, labeled "Cracking Effort")
Epicevery 12 months
Explorer 1st stageevery 12 months
FDX-10every 12 monthsFirst: 137 - 139 psi (preferred 138 psi); First: 137 - 139 psi (preferred 138 psi)
FDXievery 12 monthsFirst: 134-142 psi (supply 500-3000 psi)
GT3every 12 monthsSecond: 1.2 in H2O or less (minimum effort with no leak), at IP 138 psi
Omega 2every 12 months
Omega 3every 12 months
Pre 95 BPevery 12 months
PX2every 12 monthsFirst: 138 - 142 PSI
PX3every 12 months
Slimlineevery 12 monthsSecond: 1.5 - 1.8 in H2O
SP4every 12 monthsFirst: 140 +/-5 psi (9.5 +/-0.3 bar)
SP5every 12 monthsFirst: 145-150 psi at 3000 psi supply; 125-135 psi at 500 psi supply
TDX-5every 12 monthsFirst: 140 +/-5 psi (9.5 +/-0.3 bar)
Zeoevery 12 monthsSecond: <=1.2 IWC at IP 138 psi +/-2 (Venturi switch negative) per the manual's OPENING EFFORT spec block. CAUTION: the same manual's Final Adjustment step 9 states <=1.4 IWC twice. Internal conflict in Doc. 12-2823-r02 - confirm with Huish before tuning.
Zetaevery 12 months

OMS

ModelServiceBench spec
Airstreamevery 12 monthsFirst: 140 psi ±5 (135-145 psi)
R236every 12 months
R250every 12 months
R600every 12 monthsFirst: 145 psi lock-up; acceptable range 130-145 psi

Poseidon

ModelServiceBench spec
Cyklonevery 24 monthsFirst: <171 PSI @ 500 PSI; Second: 1.1 - 1.6 in H2O
Cyklon 1st stageevery 24 monthsFirst: <171 PSI @ 500 PSI
Cyklon 300every 24 monthsFirst: 174 psi / 12 bar max (set from 11.5 bar); at max tank pressure must not drop below 116 psi / 8 bar. Un-balanced 1st stages 3070 and 2305.; Second: 1.1 - 1.6 in H2O
Cyklon 5000every 24 monthsFirst: 167 psi / 11.5 bar, +/- 22 psi (1.5 bar). Balanced 1st stages 3257 / 3585 (art. 2950) and 3720 / 3720-10 (art. 3950).; Second: 1.1 - 1.6 in H2O
Cyklon Xevery 24 monthsSecond: 1.1 - 1.6 in H2O
Cyklon X 1st stageevery 24 monthsFirst: <171 PSI @ 500 PSI
Jetstreamevery 24 monthsSecond: 1.18 - 1.57 in H2O (30 - 40 mm), measured as diaphragm depth below the surface per the field method.; First: <145 PSI; Second: 1.18 - 1.57 in H2O (30 - 40 mm), measured as diaphragm depth below the surface per the field method.
Odinevery 24 months
Thorevery 24 months
Xstreamevery 24 monthsFirst: Adjustable 1st stage: 122 - 125 psi (8.4 - 8.6 bar). Unadjustable 1st stage: 116 - 160 psi (8 - 11 bar). Nominal inter-stage pressure 123 psi (8.5 bar).; Second: 1.1 - 1.6 in H2O; First: Adjustable 1st stage: 122 - 125 psi (8.4 - 8.6 bar). Unadjustable 1st stage: 116 - 160 psi (8 - 11 bar). Nominal inter-stage pressure 123 psi (8.5 bar).; Second: 1.1 - 1.57 in H2O (CP 274 - 392 Pa, approx. 28 - 40 mm w.c.). Adjust with tool 2705.

Problue

ModelServiceBench spec
FS-870Bevery 12 months

Scubair

ModelServiceBench spec
Scubair Sonicevery 12 months

Scubapro

ModelServiceBench spec
109every 24 months
156every 24 months
A700every 24 monthsSecond: 1.0 - 1.5 in H2O
AIR IIevery 24 monthsSecond: 1.0 - 1.5 in H2O
Air2every 24 months
C200every 24 months
C300every 24 months
C350every 24 months
C370every 24 months
D300every 24 months
D350every 24 months
D400every 24 monthsSecond: 1.0 - 1.5 in H2O
D420every 24 months
G200every 24 monthsSecond: 1.0 - 1.5 in H2O
G200Bevery 24 monthsSecond: 1.0 - 1.5 in H2O
G250every 24 months
G250Vevery 24 months
G260every 24 monthsSecond: 1.0 - 1.2 in H2O
G500every 24 monthsSecond: 1.1 - 1.3 in H2O
Mark 1every 24 months
Mark 2every 24 monthsFirst: 125-145 psi
Mark 5every 24 monthsFirst: 125-145 psi
Mark 7every 24 monthsFirst: 125-145 psi
MK 2every 24 monthsFirst: 125-145 psi
MK 5every 24 monthsFirst: 125 - 145 PSI
Mk10every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI; First: 125 - 145 PSI
Mk10 Plusevery 24 monthsFirst: 125 - 145 PSI
Mk11every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk14every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk15every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk16every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk17every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk17 EVOevery 24 monthsFirst: 125 - 145 PSI
Mk18every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk19 EVOevery 24 monthsFirst: 130-140 psi (9.0-9.7 bar)
Mk2 EVOevery 24 monthsFirst: 125-135 psi (8.6-9.3 bar)
Mk2 Plusevery 24 monthsFirst: 125-135 psi (8.6-9.3 bar)
Mk20every 24 monthsFirst: 130-140 psi (9.0-9.7 bar)
Mk20 ULevery 24 monthsFirst: 130-140 psi (9.0-9.7 bar)
Mk200every 24 monthsFirst: 125-145 PSIG (checked at both 300 and 3000 PSIG supply)
Mk21every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk25every 24 monthsFirst: 125 - 145 PSI; First: 125 - 145 PSI
Mk25 EVOevery 24 monthsFirst: 125 - 145 PSI
Mk25Tevery 24 monthsFirst: 125 - 145 PSI
R095every 24 monthsSecond: 1.2 - 1.4 in H2O; Second: 1.2 - 1.4 in H2O
R109every 24 months
R156every 24 months
R190every 24 monthsSecond: 1.2 - 1.4 in H2O
R190 Octoevery 24 monthsSecond: 1.5 - 1.8 in H2O
R195every 24 monthsSecond: 1.2 - 1.4 in H2O
R295every 24 monthsSecond: 1.2 - 1.4 in H2O
R295 Octoevery 24 monthsSecond: 1.5 - 1.8 in H2O
R390every 24 monthsSecond: 1.2 - 1.4 in H2O
R390 Octoevery 24 monthsSecond: 1.5 - 1.8 in H2O
R395every 24 monthsSecond: 1.2 - 1.4 in H2O
S550every 24 monthsSecond: 1.0-1.4 (S600-S550 Repair Guide)
S555every 24 monthsSecond: 1.1 - 1.3 in H2O
S560every 24 monthsSecond: 1.1 - 1.3 in H2O
S600every 24 monthsSecond: 1.1 - 1.3 in H2O
S620 X-Tievery 24 months
S620Tievery 24 months
X650every 24 monthsSecond: 1.0 - 1.5 in H2O

Scubatech

ModelServiceBench spec
R2 ICEevery 12 months

Seac

ModelServiceBench spec
Diamondevery 12 months
DX200every 12 months
IT300every 12 months
P-Synchroevery 12 months
PX100every 12 months
Soriusevery 12 months
Synchroevery 12 months
X-10every 12 months
X-100every 12 months

SeaQuest

ModelServiceBench spec
(Apeks XTX-based)every 12 monthsFirst: 135 psi ±5 (130-140 psi) — Apeks family figure; confirm against this model's own manual
AirSourceevery 12 monthsSecond: 1.0 - 1.5 in H2O
Centuryevery 12 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Infinityevery 12 monthsSecond: 1.0 - 1.5 in H2O
Mirageevery 12 monthsSecond: 1.0 - 1.5 in H2O
Spectrumevery 12 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
XR2every 12 monthsFirst: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O

Sherwood

ModelServiceBench spec
4000every 12 months
9000 Series 1st stageevery 12 monthsFirst: 135-145 psi (9.3-10.0 bar)
Blizzardevery 12 monthsFirst: 135-145 psi (9.3-10.0 bar); First: 135-145 psi (9.3-10.0 bar); Second: old <=1.0; new <=2.0 at opening (VERIFIED)
Blizzard Pro 1st stageevery 12 monthsFirst: 135-145 psi (9.3-10.0 bar)
Brutevery 12 monthsFirst: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O; First: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O
Brut Proevery 12 monthsFirst: 130 - 150 PSI
Gemini 1st stageevery 12 months
Legacyevery 12 months
Magnumevery 12 monthsFirst: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O; First: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O
Magnum IIevery 12 monthsFirst: 130 - 150 PSI
Magnum Pro 1st stageevery 12 monthsFirst: 130 - 150 PSI
Maximusevery 12 monthsFirst: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O; First: 130 - 150 PSI
Oasisevery 12 monthsFirst: 130 - 150 PSI; First: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O; First: 130 - 150 PSI; Second: 1.0 - 1.5 in H2O
Oasis Pro 1st stageevery 12 monthsFirst: 130 - 150 PSI
Octoevery 12 monthsSecond: 1.5 - 1.8 in H2O
Shadowevery 12 months
SR1every 12 monthsFirst: 125 - 145 PSI; Second: < 2.0 in H2O; First: 125 - 145 PSI
SR2every 12 monthsFirst: 135-145 psi (9.3-10.0 bar); Second: <=1.5 at opening (VERIFIED, QC inspection ceiling, not the setpoint)
SR3every 12 monthsFirst: 135-145 psi (9.3-10.0 bar)

Spiro (La Spirotechnique)

ModelServiceBench spec
Spiro Arcticevery 12 months
Spiro Supraevery 12 months

Spirotechnique

ModelServiceBench spec
Calypsoevery 12 months

Sportsways

ModelServiceBench spec
Waterlung Dual Airevery 12 months
Waterlung Hydro Twinevery 12 months
Waterlung Hydro Twin IIevery 12 months
Waterlung Malibu Diverevery 12 months
Waterlung Nautilusevery 12 months
Waterlung Sport Diver IIevery 12 months

Subgear

ModelServiceBench spec
Arubaevery 12 monthsFirst: 145 @ 3000 PSIG; Second: 1.2 - 1.4 in H2O
Aruba Octopusevery 12 monthsSecond: 1.5 - 1.8 in H2O
Bonaireevery 12 months
Caymanevery 12 monthsFirst: 130 @ 3000 PSIG; Second: 1.1 - 1.3 in H2O
SG10every 12 months
SG20every 12 months
SG30every 12 months
SG50every 12 months
SG500every 12 months

Swimaster

ModelServiceBench spec
Trieste R22every 12 months

Technisub

ModelServiceBench spec
Spiro Clubevery 12 months

Tecline / Scubatech

ModelServiceBench spec
R1 PROevery 12 monthsFirst: 123 (8.5 bar) psi (8.5 bar)
R2 TECevery 12 monthsFirst: 130-145 (9-10 bar) psi (9-10 bar)
R4 TECevery 12 monthsFirst: 130-145 (9-10 bar) psi (9-10 bar)
R5 TECevery 12 monthsFirst: 130-145 (9-10 bar) psi (9-10 bar)
REC1every 12 months
TEC1every 12 months
TEC2every 12 months
V1 ICEevery 12 monthsFirst: 123 (8.5 bar) psi (8.5 bar)
V2 ICEevery 12 monthsFirst: 130-145 (assumed) psi (9-10 bar)

Tusa

ModelServiceBench spec
Air Duoevery 12 monthsSecond: 1.2 - 1.6 in H2O
Imprexevery 12 months
R-100every 12 monthsFirst: 135-145 psi
R-200every 12 monthsFirst: 130-140 psi (9.1-9.8 bar)
R-300every 12 monthsFirst: 139-144 psi (9.5-9.8 bar)
R-400every 12 monthsFirst: 125-145 psi (8.5-9.8 bar); set 145 psi, drops to ~140 after bedding
R-500every 12 monthsFirst: 135-145 psi (set 140-145; must never drop below 125 psi)
R-600every 12 monthsFirst: 135-145 psi (9.3-10 bar)
R-700every 12 monthsFirst: 135-145 psi (9.3-10 bar)
R700every 12 monthsFirst: 135-145 psi (9.3-10 bar)
RS-1001every 12 months
RS-1103every 12 months
RS-1301every 12 months
RS-460 IIevery 12 months
RS-811every 12 monthsFirst: Set IP to 140-145 psi, bed in 30-60 cycles; IP then drops to 135-140 psi (9.5 bar). Spec sheet: 125-145 psi (8.5-9.5 bar) over ambient after bedding in; never below 125 psi.; Second: Primary: 1.0 to 1.4 in H2O; Secondary (Octopus): 1.5 to 2.0 in H2O (Magnehelic inhalation effect, tested with IP 135-145 psi)
RS-812every 12 months
S-20every 12 monthsSecond: Primary: 1.0 to 1.5 in H2O; Secondary (Octopus): 1.5 to 2.0 in H2O (Magnehelic inhalation effect, tested with IP 125-145 psi)
S-30every 12 monthsSecond: S-30 & S-40: approx 1 in H2O; S-50: approx 1.33 in H2O (0.34 kPa / 34 mm)
S-60every 12 monthsSecond: S-60: 1.2 to 1.8 in H2O (30-45 mm). S-90: Primary 1.0 to 1.4 in H2O; Octopus 1.5 to 2.0 in H2O. Manuals differ - use the figure for the second stage actually on the bench.
S-70every 12 monthsSecond: Primary: 1.0 to 1.5 in H2O; Secondary (Octopus): 1.5 to 2.0 in H2O (Magnehelic inhalation effect, tested with IP 135-145 psi)
S-80every 12 monthsSecond: Primary: 1.0 to 1.5 in H2O; Secondary (Octopus): 1.5 to 2.0 in H2O (Magnehelic inhalation effect, tested with IP 135-145 psi)
S30every 12 monthsSecond: approx 1 in H2O (manual gives a single target, not a range)

US Divers

ModelServiceBench spec
Calypsoevery 12 months
Conshelfevery 12 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O
Conshelf 20every 12 months
Conshelf 21every 12 months
Conshelf 22every 12 months
Conshelf 30every 12 months
Conshelf VIevery 12 months
Conshelf VIIIevery 12 months
Conshelf XIevery 12 months
Conshelf XIIevery 12 months
Conshelf XII Arcticevery 12 months
Micraevery 12 monthsSecond: 1.0 - 1.5 in H2O
Octopusevery 12 monthsSecond: 1.0 - 1.5 in H2O
SEAevery 12 monthsFirst: 125 - 145 PSI; Second: 1.0 - 1.5 in H2O

US Divers/Aqua Lung

ModelServiceBench spec
Aquariusevery 12 months
Conshelf XIVevery 12 months
Impulseevery 12 months

Voit

ModelServiceBench spec
Avalonevery 12 months
Trieste II V22every 12 months
V22 Polaris 50every 12 months
V66 Navyevery 12 months
VCR-2 "50 Fathom"every 12 months
VR-1 Sportsmanevery 12 months
VR-2 Marinerevery 12 months

Voit/AMF Swimaster

ModelServiceBench spec
MR12every 12 months

Voit/Swimaster

ModelServiceBench spec
Titanevery 12 months

Voit/Voit Swimaster

ModelServiceBench spec
40 Fathomevery 12 months

White Stag

ModelServiceBench spec
Deep 1every 12 months
Deep Ievery 12 months
Depth Finderevery 12 months
Sea Lungevery 12 months

XS Scuba

ModelServiceBench spec
Brawnevery 12 monthsFirst: 130-150 psi
Highland Compactevery 12 monthsFirst: 135-145 psi
Highland Vortexevery 12 monthsSecond: 0.9 - 2.0 in H2O
Hookah 2nd Stageevery 12 monthsSecond: 0.9 - 2.0 in H2O
Inspireevery 12 monthsFirst: 130 - 145 PSI; Second: 1.0-1.4 in H2O
Pony Regulatorevery 12 monthsSecond: 0.9 - 2.0 in H2O
Questevery 12 monthsFirst: 130 - 145 PSI; Second: 0.9 - 2.0 in H2O
Standardevery 12 monthsSecond: not to exceed 1.5-2.0 in H2O
Vortexevery 12 monthsFirst: 130 - 145 PSI
Xploreevery 12 monthsFirst: 130 - 145 PSI; Second: 0.9 - 2.0 in H2O

Zeagle

ModelServiceBench spec
DS-50every 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 150 psig (10.2 bar).
DS-IVevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 145 psi (10 bar).
DS-Vevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 150 psig (10.2 bar).
DVevery 12 months
Envoyevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal (non-CE). CE (EN250) certified units: 120-125 psi (8-8.6 bar), 123 psi / 8.5 bar nominal. Never set above 150 psig (10.2 bar).; Second: Not to exceed 2.0 in H2O (50 mm w.c.) at cracking with the adjuster knob in the minimum effort position. The Envoy service manual publishes no lower limit and does not name a Deluxe variant separately.
Envoy Deluxeevery 12 months
Envoy IIevery 12 monthsFirst: 135-145 psi when inlet pressure is 500-3000 psi.
Envoy II Octoevery 12 monthsSecond: 1.0 - 1.4 in H2O, set with IP at 145 psi.
F8every 24 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal (347-8300 F8 service manual). F8 schematics 310-8310/8320 instead specify 135-145 psi at 500-3000 psi inlet. Never set above 150 psig (10.2 bar).; Second: Primary: 1.0 - 1.5 in H2O; must not exceed 2.0 in H2O (50 mm) at min effort. Octopus: 1.5 - 2.0 in H2O (38-50 mm). F8 2nd-stage schematic instead calls for 1.2 - 1.25 in H2O at IP 145 psi.
Flathead VIevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 145 psi (10 bar).
Flathead VIIevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 150 psig (10.2 bar).
Flathead XPevery 12 months
Octo+every 12 months
Onyxevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 150 psig (10.2 bar).
Onyx IIevery 12 monthsFirst: 135-145 psi when inlet pressure is 500-3000 psi.; Second: 1.0 - 1.4 in H2O, set with IP at 145 psi.
RaZorevery 12 monthsFirst: 120-140 psi (8.3-9.7 bar) @ 3000 psi inlet. Unbalanced piston: set IP at the highest cylinder pressure the reg will see (3000-3500 psi). Manual body 4.5.10 states 120-150 psi @ 3000 psi; never above 160 psig.; Second: Not to exceed 2.0 in H2O (50 mm w.c.) at cracking with the adjuster knob in the minimum effort position. No lower limit published; the RaZor manual's 2nd-stage section is the Envoy second stage.
ReZortevery 12 months
ZXevery 12 monthsFirst: 130-145 psi (9-10 bar), 135 psi / 9.3 bar nominal. Never set first stage output above 150 psig (10.2 bar).; Second: 0.7-1.3 in H2O ideal; primary not to exceed 2.0 in H2O at min-effort knob position; octopus 1.5-2.0 in H2O

Buying used? Start with how to inspect a used regulator or browse the certified used regulators in stock.